Where Exploration Meets Excellence
Jupiter Academy · Lesson

Integrated Rate Equations for First-Order Reactions

integrated rate equations for zero-order reactions
integrated rate equations for zero-order reactionsImage via Pixabay

First-order kinetics describes an extraordinary range of processes, from the decomposition of dinitrogen pentoxide in a flask to the slow decay of a radioactive nucleus buried deep within the Earth. What unites these phenomena is a single, elegant condition: the rate of reaction at any instant is directly proportional to the concentration of exactly one reactant raised to the first power. This proportionality, once translated into a differential equation and integrated, yields a mathematical relationship that predicts concentration at any moment in time. That relationship is the integrated rate law for first-order reactions, and it is the analytical engine behind an enormous share of practical chemistry.

A schematic graph of reactant concentration [R] on the vertical axis against time t on the horizontal axis, showing a straight descending line from an intercept [R]₀ with slope −k, plus a small inset of the reaction R → P.
For a zero-order reaction the reactant concentration falls in a straight line with time, at a constant rate k.Programmatically generated contextual illustration.

Building directly on the zero-order case studied previously, this lesson moves from the differential rate expression to its integrated form, then extracts the three working equations that chemists actually use in the laboratory: the exponential decay law, the natural-logarithm plot, and the base-10 logarithm formula. Each form serves a distinct purpose. The exponential form predicts future concentrations, the logarithmic forms allow the rate constant to be extracted from experimental data, and the graphical method provides a visual diagnostic for confirming that a reaction truly obeys first-order behaviour rather than merely appearing to do so.

Beyond the derivation, the lesson develops the practical craft of first-order analysis. Gas-phase reactions monitored through total pressure, pseudo-first-order systems where a second reactant is held in vast excess, and radioactive decay dating all rely on the same underlying mathematics. Worked examples, a careful treatment of common errors, and a practice problem on carbon-14 dating round out the discussion, preparing the ground for the next lesson on half-life, where the constant half-life of first-order reactions becomes a powerful analytical tool in its own right.

From the Differential Rate Law to the Integrated Equation

The starting point for any first-order analysis is the differential rate law itself. For a reaction in which a single reactant R converts into products, first-order behaviour means the instantaneous rate is proportional to the first power of the reactant concentration. Writing the rate as the negative of the rate of change of concentration gives a compact differential equation that captures the entire kinetic behaviour of the system. Everything that follows — the exponential decay, the straight-line plots, the half-life formula — is a consequence of solving this one equation under the boundary condition that the concentration equals its initial value at time zero.

Setting Up and Solving the Differential Equation

The differential form is written as the rate of disappearance of R equalling the product of the rate constant and the concentration: ##-\dfrac{d[R]}{dt} = k[R]##. Separating the variables places all concentration terms on one side and all time terms on the other, giving ##\dfrac{d[R]}{[R]} = -k\,dt##. Integrating both sides between the limits of initial concentration ##[R]_0## at time zero and concentration ##[R]## at time ##t## produces the natural logarithm relationship that anchors the entire treatment. The integration is elementary but its result is profound: it converts a statement about instantaneous rates into a statement about concentrations at any two moments in time.

Carrying out the integration yields the working equation ##\ln[R] = -kt + \ln[R]_0##, which is the natural-logarithm form of the integrated rate law. Rearranging it produces the more familiar ratio expression ##\ln\dfrac{[R]_0}{[R]} = kt##, and dividing through by ##t## gives the rate constant directly: ##k = \dfrac{1}{t}\ln\dfrac{[R]_0}{[R]}##. This is the equation most often used to compute a rate constant from a single pair of concentration measurements separated by a known time interval, and it is the form that appears in virtually every textbook treatment of first-order kinetics.

The Exponential Form and Its Physical Meaning

Taking the antilogarithm of both sides of the integrated equation produces the exponential decay law ##[R] = [R]_0 e^{-kt}##, which states that concentration falls exponentially with time rather than linearly. The physical interpretation is important: the reaction never formally reaches zero concentration in finite time, but instead approaches it asymptotically. Each successive interval of fixed duration removes the same fraction of whatever reactant remains, not the same absolute amount. This fractional-removal behaviour is the defining signature of first-order kinetics and explains why the half-life of such reactions is independent of the starting concentration.

A straight line starting at [R]₀ on the y-axis and decreasing linearly with time, crossing the x-axis at [R]₀/k, showing that zero-order concentration decay has constant slope.
Concentration falls linearly with time from its initial value, with slope equal to minus the rate constant.Programmatically generated contextual illustration.

Because the decay is exponential, a plot of concentration against time produces a smooth curve that flattens progressively. Recognising this curve shape is a useful first check when examining raw data, but it is not sufficient to confirm first-order behaviour, since other reaction orders can produce superficially similar curves. The definitive test requires transforming the data into a linear form, which is precisely what the logarithmic plots accomplish. The exponential equation is therefore best regarded as a predictive tool rather than a diagnostic one, useful once the order has already been established by other means.

Graphical Methods for Confirming First-Order Behaviour

Graphical analysis transforms the integrated rate law into a visual test that is both rigorous and easy to apply. Comparing the natural-logarithm equation with the general equation of a straight line, ##y = mx + c##, reveals a direct correspondence: plotting ##\ln[R]## on the vertical axis against time on the horizontal axis should yield a straight line whose slope equals ##-k## and whose intercept equals ##\ln[R]_0##. A linear plot of this kind is strong evidence of first-order kinetics, and the slope delivers the rate constant without any additional calculation. The method is robust because it uses every data point simultaneously rather than relying on a single pair of measurements.

The Natural Logarithm Plot and Its Slope

Constructing the ##\ln[R]## versus ##t## plot requires converting each measured concentration into its natural logarithm before plotting. If the resulting points fall on a straight line, the reaction is first order in that reactant, and the negative of the slope gives the rate constant in units of reciprocal time. A useful refinement is to compare this plot with the corresponding zero-order test, where concentration itself is plotted against time. Whichever transformation produces the straighter line identifies the correct order, making the graphical method a practical discriminator between competing kinetic models rather than merely a confirmation tool.

A catalyst surface whose active sites are all occupied by adsorbed reactant molecules, with bulk reactant above and product molecules leaving, illustrating that the fixed number of occupied sites sets a constant rate.
When every active site is occupied, added reactant cannot raise the rate, so conversion proceeds at a constant zero-order pace.Programmatically generated contextual illustration.

Two subtleties deserve attention. First, the intercept of the ##\ln[R]## plot equals ##\ln[R]_0##, so the initial concentration can be recovered by exponentiating the intercept, providing an internal consistency check on the data. Second, the units of the slope are reciprocal time, so a slope of ##-0.0304\ \text{min}^{-1}## corresponds to a rate constant of ##0.0304\ \text{min}^{-1}##. Careless sign handling is a frequent source of error here, since the slope is negative while the rate constant is positive by convention. Always report the rate constant as a positive quantity and note that the slope carries the negative sign.

The Base-10 Logarithm Form and the Ratio Plot

Because laboratory data are often handled with base-10 logarithms, the integrated rate law is frequently expressed in the form ##k = \dfrac{2.303}{t}\log\dfrac{[R]_0}{[R]}##, where the factor 2.303 is the conversion between natural and common logarithms, ##\ln 10##. Plotting ##\log\dfrac{[R]_0}{[R]}## against time produces a straight line through the origin with slope equal to ##k/2.303##. This ratio plot is particularly convenient because it passes through the origin by construction, so any systematic deviation from linearity is immediately visible as curvature or as a non-zero intercept.

The choice between the natural-logarithm and base-10 forms is purely a matter of convenience; both encode identical information and yield the same rate constant when applied correctly. The base-10 form is common in older textbooks and in examination settings where logarithm tables or simple calculators are used, while the natural-logarithm form dominates in modern computational work. Students should be fluent in both, since examination questions frequently specify one form and expect the answer in the corresponding units. Converting between them requires only the factor 2.303, applied consistently to avoid arithmetic slips.

Equation Reference

First-Order Rate Law: Equivalent Forms and Their Uses

Each algebraic form of the integrated rate law serves a distinct analytical purpose.

Form of the Law Primary Application
##\ln[R] = -kt + \ln[R]_0## Linear plot of ln[R] vs t; slope gives −k
##[R] = [R]_0 e^{-kt}## Predicting concentration at any future time
##k = \dfrac{2.303}{t}\log\dfrac{[R]_0}{[R]}## Computing k from two concentration readings
##\log\dfrac{[R]_0}{[R]} = \dfrac{k}{2.303}t## Ratio plot through origin; slope = k/2.303
Note:
  • The factor 2.303 equals ln 10 and converts between natural and common logarithms.
  • All four forms are mathematically identical; choose the one matching the data available.

Worked Examples Using the Logarithmic Form

The logarithmic form of the integrated rate law is the workhorse of practical kinetics, and working through representative calculations builds the fluency needed for examinations and laboratory work. The general strategy is consistent: identify the initial and final concentrations, note the time interval separating them, and substitute into ##k = \dfrac{2.303}{t}\log\dfrac{[R]_0}{[R]}##. Careful attention to units, significant figures, and the distinction between the initial concentration and the concentration at the start of the measurement interval prevents most errors. The examples below illustrate the method across solution-phase and gas-phase systems.

Decomposition of Dinitrogen Pentoxide in Solution

Consider the first-order decomposition of dinitrogen pentoxide, ##N_2O_5(g) \rightarrow 2NO_2(g) + \dfrac{1}{2}O_2(g)##, at 318 K. The initial concentration of ##N_2O_5## is ##1.24 \times 10^{-2}\ \text{mol L}^{-1}##, and after 60 minutes the concentration has fallen to ##0.20 \times 10^{-2}\ \text{mol L}^{-1}##. Substituting into the logarithmic form gives ##k = \dfrac{2.303}{60\ \text{min}}\log\dfrac{1.24 \times 10^{-2}}{0.20 \times 10^{-2}}##. The concentration ratio is 6.2, whose logarithm is approximately 0.792, so the rate constant evaluates to ##k = 0.0304\ \text{min}^{-1}##.

Two curves: a straight rising line for zero-order half-life proportional to initial concentration, and a flat horizontal line for first-order half-life independent of concentration.
The zero-order half-life rises with initial concentration while the first-order half-life stays constant.Programmatically generated contextual illustration.

This example illustrates several practical points. The units of the rate constant are reciprocal minutes because the time was expressed in minutes; had the interval been given in seconds, the result would have been ##5.07 \times 10^{-4}\ \text{s}^{-1}##. The concentration ratio is dimensionless, so the units of concentration cancel and do not affect the calculation. Finally, the answer should be reported to three significant figures, consistent with the precision of the input data. Checking that the rate constant is positive and of a plausible magnitude for a gas-phase decomposition at moderate temperature provides a useful sanity check.

Gas-Phase Reactions Monitored by Total Pressure

Many gas-phase reactions are conveniently followed by measuring total pressure at constant volume rather than concentration directly. For a reaction of the type ##A(g) \rightarrow B(g) + C(g)##, if the initial pressure of A is ##p_i## and the total pressure at time t is ##p_t##, a simple stoichiometric accounting shows that the partial pressure of A at time t equals ##2p_i - p_t##. The integrated rate law then becomes ##k = \dfrac{2.303}{t}\log\dfrac{p_i}{2p_i - p_t}##, allowing the rate constant to be extracted directly from pressure readings without any need to measure partial pressures individually.

A concrete case is the thermal decomposition of ##N_2O_5## at constant volume, ##2N_2O_5(g) \rightarrow 2N_2O_4(g) + O_2(g)##. If the pressure of ##N_2O_5## falls by ##2x##, the pressure of ##N_2O_4## rises by ##2x## and that of ##O_2## by ##x##, so the total pressure equals ##0.5 + x## when the initial pressure is 0.5 atm. The partial pressure of ##N_2O_5## is therefore ##1.5 - 2p_t##. At 100 s the total pressure is 0.512 atm, giving a partial pressure of ##1.5 - 1.024 = 0.476## atm and a rate constant computable directly from the logarithmic formula.

A straight line falling from 0.80 mol per litre at time zero to zero, with the point at half the initial concentration marked at the unknown half-life.
Concentration against time for the zero-order reaction of the worked example, with the half-life marked.Programmatically generated contextual illustration.
A straight line falling from 0.50 mol per litre at time zero, with the level 0.20 mol per litre marked and the corresponding time marked as unknown.
Concentration against time for the practice problem, showing the initial and target concentrations and the unknown time.Programmatically generated contextual illustration.
Worked Data

Pressure Data for N2O5 Decomposition at Constant Volume

Total pressure readings converted into partial pressure of the reactant.

Quantity Value at t = 0 Value at t = 100 s
Total pressure (atm) 0.500 0.512
Partial pressure of N2O5 (atm) 0.500 0.476
Extent variable x (atm) 0.000 0.012
Note:
  • Partial pressure of N2O5 is obtained from ##p_{N_2O_5} = 1.5 - 2p_t##.
  • Stoichiometry: two moles of N2O5 yield two of N2O4 and one of O2.

Pseudo-First-Order Reactions and the Excess Reagent Technique

Many reactions that are genuinely second order overall behave as though they were first order under carefully chosen experimental conditions. The classic example is the acid-catalysed hydrolysis of ethyl acetate in water, ##CH_3COOC_2H_5 + H_2O \rightarrow CH_3COOH + C_2H_5OH##. The true rate law is second order, first in ester and first in water, but in dilute aqueous solution the concentration of water is so vastly greater than that of the ester that it remains essentially constant throughout the reaction. The water concentration can therefore be absorbed into the rate constant, producing an effective first-order law in the ester alone.

Why Excess Reagent Simplifies the Rate Law

When one reactant is present in large excess, its concentration changes negligibly as the reaction proceeds, so the term involving it becomes effectively constant. Mathematically, if the true rate law is ##\text{rate} = k[A][B]## and ##[B] \gg [A]##, then ##[B] \approx [B]_0## throughout, and the rate simplifies to ##\text{rate} = k'[A]## where ##k' = k[B]_0##. The measured constant ##k'## is called the pseudo-first-order rate constant, and it carries units of reciprocal time even though the underlying reaction is second order. Dividing ##k'## by the known excess concentration recovers the true second-order constant ##k##.

This technique is enormously valuable in practice because it allows second-order reactions to be analysed with the simpler first-order mathematics. The graphical test is identical: a plot of ##\ln[A]## against time should be linear, and the slope yields ##k'##. Varying the excess concentration of B across a series of experiments and plotting ##k'## against ##[B]_0## should produce a straight line through the origin whose slope is the true rate constant ##k##. This two-stage procedure is a standard method for determining the order with respect to a reactant that is inconvenient to vary directly.

Recognising Pseudo-First-Order Behaviour in Practice

Pseudo-first-order conditions arise whenever a solvent participates in the reaction, whenever a catalyst is present at constant concentration, or whenever one reagent is deliberately supplied in large excess to simplify analysis. The hydrolysis of sucrose in acidic solution, the inversion of cane sugar, is another classic example: the reaction is first order in sucrose and effectively zero order in water because water is the solvent. In all such cases, the observed kinetics reflect the rate-determining dependence on the limiting reagent, and the pseudo-first-order constant is a composite quantity that depends on the concentration of the excess species.

A common mistake is to report a pseudo-first-order constant as though it were the true rate constant of the reaction. This is misleading because the pseudo-constant changes if the excess concentration changes. Always specify the conditions under which a pseudo-first-order constant was measured, and convert to the true constant whenever the excess concentration is known. In examination answers, stating explicitly that the reaction is pseudo-first-order, and identifying which species is in excess, demonstrates the depth of understanding that distinguishes a complete answer from a superficial one.

Determining Reaction Order from Graphical Analysis

The order of a reaction is rarely obvious from inspection and must be established experimentally. Graphical analysis provides the most reliable route, because it tests the integrated rate laws for different orders against the same dataset and identifies which one produces a straight line. For a zero-order reaction, concentration plotted against time is linear. For a first-order reaction, the natural logarithm of concentration against time is linear. For a second-order reaction, the reciprocal of concentration against time is linear. Applying all three transformations to a single dataset and comparing the linearity of the resulting plots is a standard and defensible procedure.

Comparing Zero-, First-, and Second-Order Plots

The discriminating power of the method lies in the fact that only one transformation will linearise the data if the reaction has a well-defined order. A dataset that appears curved on a concentration-versus-time plot may become perfectly straight when the logarithm is taken, confirming first-order behaviour. Conversely, a dataset that is already linear on the concentration plot indicates zero order, and taking logarithms would introduce curvature. The coefficient of determination, or ##R^2## value, from a linear regression provides a quantitative measure of which transformation fits best, and modern data-analysis software makes this comparison straightforward.

It is worth emphasising that the graphical method tests the order with respect to the species whose concentration is being monitored. If a reaction involves multiple reactants, the order with respect to each must be determined separately, typically by the isolation method in which all but one reactant are held in excess. The overall order is then the sum of the individual orders. This systematic approach, combining graphical analysis with the isolation technique, is the foundation of experimental kinetics and underlies the determination of rate laws for reactions of arbitrary complexity.

Interpreting Deviations from Linearity

Real experimental data rarely fall perfectly on a straight line, and interpreting deviations correctly is an essential skill. Random scatter about a straight line is expected and does not invalidate the first-order assignment, provided the scatter is small relative to the overall trend. Systematic curvature, however, signals a problem: the reaction may be of mixed or changing order, the temperature may have drifted during the experiment, or a side reaction may be consuming or producing the monitored species. Distinguishing random noise from systematic deviation requires plotting residuals and examining whether errors are evenly distributed or show a pattern.

Another source of apparent non-linearity is the approach to equilibrium in a reversible reaction. If the reaction does not proceed essentially to completion, the simple integrated rate law no longer applies, and a modified treatment accounting for the equilibrium concentration is required. Similarly, if the reaction is autocatalytic, the rate may increase initially before falling, producing a sigmoidal rather than a simple exponential curve. Recognising these possibilities prevents the misassignment of reaction order and encourages a more careful design of kinetic experiments.

Order Test

Diagnostic Plots for Reaction Order

Which transformation linearises the data identifies the reaction order.

Order Linear Plot Slope
Zero [R] vs t −k
First ln[R] vs t −k
Second 1/[R] vs t +k
Note:
  • Only one transformation should linearise a dataset of well-defined order.
  • Use ##R^2## values to compare fits quantitatively.

Radioactive Decay, Carbon-14 Dating, and the Constant Half-Life

All natural and artificial radioactive decay of unstable nuclei follows first-order kinetics, because the probability that any given nucleus decays in a unit of time is constant and independent of how many nuclei are present. The rate of decay is therefore proportional to the number of radioactive nuclei, exactly mirroring the first-order rate law for chemical reactions. This correspondence makes radioactive decay the most elegant natural demonstration of first-order behaviour, and it underpins applications ranging from medical imaging to geological dating. The mathematics is identical to that developed for chemical systems, with the number of nuclei replacing concentration.

Applying First-Order Kinetics to Carbon-14 Dating

Carbon-14 is produced continuously in the upper atmosphere and incorporated into living organisms through photosynthesis and the food chain. While an organism is alive, its carbon-14 content remains in equilibrium with the atmosphere, but upon death the uptake ceases and the carbon-14 begins to decay with a half-life of approximately 5730 years. Because the half-life of a first-order process is constant and independent of the initial amount, the fraction of carbon-14 remaining in a sample directly encodes the time elapsed since death. Measuring the residual activity therefore provides a radiocarbon age.

As a practice problem, suppose a wooden artefact retains 25 percent of its original carbon-14 content. Since each half-life reduces the amount by a factor of two, 25 percent corresponds to two half-lives, giving an age of approximately ##2 \times 5730 = 11460## years. More generally, the age can be computed from ##t = \dfrac{2.303}{k}\log\dfrac{N_0}{N}##, where ##k = \dfrac{0.693}{t_{1/2}}##. This calculation demonstrates how the constant half-life of first-order reactions converts a simple activity measurement into a quantitative chronological tool, a theme developed fully in the next lesson.

Why the Half-Life Is Independent of Initial Concentration

Setting ##[R] = [R]_0/2## in the integrated rate law and solving for time gives the half-life expression ##t_{1/2} = \dfrac{\ln 2}{k} = \dfrac{0.693}{k}##, which contains no concentration term whatsoever. This is the most distinctive feature of first-order kinetics: the time required for half the reactant to disappear is the same whether the starting concentration is high or low. The physical reason is that the rate is proportional to the amount present, so when twice as much material is present the reaction proceeds twice as fast, exactly compensating for the larger quantity to be consumed.

A concentration-time curve that is a straight declining line at high concentration and bends into a decaying exponential at low concentration, marking the switch from zero-order to first-order behaviour.
Illustrative curves show concentration falling linearly while sites are saturated, then curving exponentially once the surface is no longer fully covered.Programmatically generated contextual illustration.

This constancy has practical consequences. It means that a first-order reaction can be characterised by a single number, the half-life, which is independent of the conditions of the experiment provided the temperature is fixed. It also means that after n half-lives the remaining fraction is ##(1/2)^n##, a relationship that allows rapid estimation of concentrations without detailed calculation. The half-life concept, its derivation, and its many applications form the subject of the next lesson, where the groundwork laid here is extended into a full analytical framework.

Dating Table

Carbon-14 Decay: Fraction Remaining After Successive Half-Lives

Half-life of carbon-14 taken as 5730 years; fraction remaining follows (1/2)^n.

Half-Lives Elapsed Fraction Remaining Approximate Age (years)
1 50% 5,730
2 25% 11,460
3 12.5% 17,190
4 6.25% 22,920
Note:
  • Fraction remaining after n half-lives is ##(1/2)^n##.
  • Practical radiocarbon dating is reliable to roughly 50,000 years.

Common Pitfalls and a Computational Check

First-order calculations are conceptually simple but arithmetically unforgiving, and a small number of recurring errors account for most lost marks in examinations and most discrepancies in laboratory reports. The most frequent is confusion between natural and common logarithms, which produces answers that are wrong by a factor of 2.303. The second is failure to convert time units consistently, so that a rate constant is reported in reciprocal seconds when the time was given in minutes. The third is sign confusion, in which the negative slope of the logarithmic plot is reported as a negative rate constant. Each of these is easily avoided with disciplined bookkeeping.

Errors of Units, Logarithms, and Signs

Units deserve particular attention because the rate constant of a first-order reaction always carries units of reciprocal time, never concentration per unit time. If a calculation yields units of mol per litre per second, the order has been misidentified or the algebra has gone wrong. Similarly, the argument of a logarithm must be dimensionless, so the concentration ratio must be formed from quantities in identical units. Mixing millimoles per litre with moles per litre inside the ratio introduces a factor of a thousand and produces a rate constant that is wrong by the logarithm of that factor.

Sign errors are best prevented by writing the integrated law in the ratio form ##\ln\dfrac{[R]_0}{[R]} = kt##, in which both sides are positive for a reaction proceeding forward in time. This form removes the temptation to attach a negative sign to the rate constant. When using the slope of a plot, remember that the slope equals ##-k##, so the rate constant is the negative of the slope. A quick dimensional and sign check at the end of every calculation catches the majority of these errors before they propagate into a final answer.

Verifying Results with a Short Script

Computational verification is a valuable habit, and a short script can confirm a hand calculation in seconds. The example below computes the rate constant for the dinitrogen pentoxide decomposition discussed earlier, then uses it to predict the concentration after a further interval. Running such a check guards against arithmetic slips and builds intuition for how the exponential decay behaves over time. The same structure can be adapted to any first-order dataset by changing the input concentrations and the time interval.


import math

# First-order decomposition of N2O5 at 318 K
R0 = 1.24e-2      # initial concentration, mol/L
Rt = 0.20e-2      # concentration after 60 min, mol/L
t = 60.0          # minutes

# Rate constant from the base-10 logarithmic form
k = (2.303 / t) * math.log10(R0 / Rt)
print(f"Rate constant k = {k:.4f} per minute")

# Predict concentration after a further 30 minutes
t2 = 90.0
R_pred = R0 * math.exp(-k * t2)
print(f"Predicted [N2O5] at 90 min = {R_pred:.4e} mol/L")

# Half-life check: constant, independent of R0
half_life = math.log(2) / k
print(f"Half-life = {half_life:.2f} minutes")

The script reproduces the hand-calculated rate constant of approximately ##0.0304\ \text{min}^{-1}## and shows how the same constant predicts concentrations at later times. The half-life emerges as roughly 22.8 minutes, a value that would be identical had the initial concentration been ten times larger or ten times smaller. This numerical confirmation reinforces the central message of the lesson: a single rate constant, extracted from one pair of measurements, governs the entire concentration-time profile of a first-order reaction, and the mathematics connecting these quantities is both exact and remarkably simple.

Error Audit

Common First-Order Errors and Their Corrections

Recurring mistakes in first-order calculations and the disciplined fix for each.

Error Correction
Using ln where log is required Apply the 2.303 factor consistently
Mismatched time units Convert all times to one unit before dividing
Reporting negative k Use the ratio form; k is always positive
Mixed concentration units in ratio Express both concentrations in identical units
Note:
  • Always perform a dimensional and sign check before finalising an answer.
  • A quick computational script catches most arithmetic slips.
Applications

First-Order Systems Across Chemistry and Beyond

Representative processes that obey first-order kinetics and the feature that unites them.

System Rate Law Key Feature
Hydrogenation of ethene Rate = k[C2H4] First order in alkene
Radioactive decay of Ra-226 Rate = k[Ra] Constant half-life
N2O5 decomposition Rate = k[N2O5] Gas-phase, pressure-monitored
Ethyl acetate hydrolysis Rate = k'[ester] Pseudo-first-order in water
Note:
  • All systems share a rate proportional to a single concentration term.
  • Pseudo-first-order systems require the excess concentration to be specified.

RESOURCES